Switching elements with permanent-magnetic blowout can only be used for DC applications. Thus polarity is important with permanent-magnetic blowout. The positive terminal bolt is clearly marked (+). Amperages are embossed in the polar strip of the blowout assembly.
To increase the breaking capacity these cam-operated switching elements feature electro-magnetic blowout by means of a tape-wound coil. They are suitable for switching DC and AC currents. Termination is irrespective of polarity. Amperages are embossed in the polar strip of the blowout assembly.
| Conv. thermal current Ith | 25 A: S008 P5, S008 G 60 A: S008 P6, S008 K |
| Rated insulation voltage Ui | 400 V |
| Pollution degree | 3 |
| Main contacts, configuration | 1 NC |
| IP rating (IEC 60529) | IP00 |
| Mechanical switching rate | 120 operations/min. |
| Electrical endurance | 10 ... 60 operations/min. depending on load |
| Mechanical endurance | > 3 million operations |
| Actuator travel | 4 mm max. |
| Actuating force | 4 N |
| Temperature range | -25 °C ... +70 °C |
| Terminals | M5: S008 P5, S008 G M6: S008 P6, S008 K |
| Weight | approx. 100 g |